ABB SF810INT-LOS-IR-T-C-W Safe Flame Scanner

Ararat |   03.12.2024 | N 40025 | 21 / today 2
ABB SF810INT-LOS-IR-T-C-W Safe Flame Scanner


SF810INT-LOS-UV-T-C-W | ABB | Uvisor™ SF810i Multi Fuel Integrated Safe Flame Scanner

Please contact me get more information

Email:[email protected]
VK/Whatsapp/Telegram:+8613667120925
Website: www.cwlyautomation.com

General Information of ABB SF810INT-LOS-IR-T-C-W Safe Flame Scanner
Manufacturer : ABB

Product ID: SF810I-LOS-IR-T-W

Catalog Description:SF810INT-LOS-IR-T-C-W

Product Type : Uvisor™ SF810i Multi Fuel Integrated Safe Flame Scanner

ABB Product Family:Combustion Instruments

Installation type : LOS = Scannerhead for Line Of Sight

Spectral range : UV

Cabling method, protection index, hazardous areas : T = Removable screw terminals (IP66/ IP67 and ATEX G/D

Housing : C-W = Conformal coating, Aluminium

Weight : 1.3 Kg

Technical specifications

Property Value

Optical sensor Technology

IR versions: Si photodiode Spectral response peak @ 920nm

IR versions: Si photodiode Spectral response peak @ 920nm

VL versions: Si photodiode Spectral response peak @ 560nm

UV versions: SiC photodiode Spectral response peak @ 280nm

UVIR version: Si + SiC photodiode1 Spectral response peak @280nm and 920nm

1 Si and SiC photodiodes signals can be processed individually or both combined as per burner opertion

Power supply voltage 24VDC (-25%, +20% = 18 ÷ 29VDC )

Power supply current 150mA typical,

Power consumption3.6W typical, 4W max

Inrush current6A peak, 2ms settling time

Flame Relay Safe Relay

Contacts: 1 NO, for each relay

240 VAC / 1.5A;

240 VDC / 100 mA

30 VDC / 300mA


Please contact me get more information

Email:[email protected]
VK/Whatsapp/Telegram:+8613667120925
Website: www.cwlyautomation.com


Minimum load 10mA, 5VDC

FFRT Flame Failure Response Time: 0.2s to 4s

Analog output (4-20mA) 4÷20 mA (R load 18 Vdc

Communication ports

Two, redundant, RS-485 serial channels configurable in Profibus or Modbus protocols.

Profibus: max speed 12 Mbit/s

Modbus: max speed 115.200 bit/s

operating temperature

482° C (900° F) for VL and IR fiber optic cables

350° C (662° F) for UV and dual sensor UVIR fiber optic cable

Housing mounting thread

1” NPT male

Cable entry thread

¾ “ NPT female (N/A for connectorized versions)

Electrical connections(terminal versions)

Removable terminals with screws

Allowable cable section:

AWG24-AWG12, 0.2-2.5mm2 for Relay contacts (J1 connector)

AWG 28-AWG16, 0,08-1.5mm2 for all other terminals


Please contact me get more information

Email:[email protected]
VK/Whatsapp/Telegram:+8613667120925
Website: www.cwlyautomation.com

Other commonly used models of ABB flame detector SF810 series:
ABB SF810-FOC-IR-Q-C-W;

ABB SF810-FOC-IR-Q;

ABB SF810-FOC-IR-T-C-W;

ABB SF810-FOC-IR-T;

ABB SF810-LOS-IR-Q-C-W;

ABB SF810-LOS-IR-Q;

ABB SF810-LOS-UV-Q-C-W;

ABB SF810-LOS-UV-Q;

ABB SF810-LOS-UV-T-C-W;
miawang Организация On site since 03. 12. 2024
О Себе
miawang
Организация On site since 03. 12. 2024
https://www.cwlyautomation.com
Write author
Report
Հավանել